Qualification of Image-Based Measurement Systems for Characterization of Sprays

  • Image-based measurement techniques become increasingly popular and expedite digitalization in chemical engineering. This article demonstrates their potential by testing two inline probes, namely modified optical multimode online probe (OMOP) and process microscope. Validations are performed with static monodisperse standards (9.2 µm to 406 µm) and fast-moving droplets (68.6 µm to 860.7 µm; 24.5 m s−1 to 11 m s−1). Screening of a lithography attests both probes great distortion-free image quality. A 1951 USAF chart attests a low optical resolution of 8 µm or 7 µm with respect to the OMOP or process microscope, respectively. The modified OMOP and process microscope reaches accuracies of 7.6 % or 5.9 % for particles and 8.2 % or 6.8 % for droplets.

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Suche bei Google Scholar
Metadaten
Verfasser*innenangaben:Jonas Schulz, Christoph Schunk, Eckhard Schleicher, Hans-Jörg Bart
URN:urn:nbn:de:hbz:386-kluedo-80011
DOI:https://doi.org/10.1002/cite.202000104
ISSN:1522-2640
Titel des übergeordneten Werkes (Englisch):Chemie Ingenieur Technik
Verlag:Wiley
Dokumentart:Wissenschaftlicher Artikel
Sprache der Veröffentlichung:Englisch
Datum der Veröffentlichung (online):12.04.2024
Jahr der Erstveröffentlichung:2021
Veröffentlichende Institution:Rheinland-Pfälzische Technische Universität Kaiserslautern-Landau
Datum der Publikation (Server):12.04.2024
Ausgabe / Heft:93/7
Seitenzahl:8
Erste Seite:1111
Letzte Seite:1118
Quelle:https://onlinelibrary.wiley.com/doi/10.1002/cite.202000104
Fachbereiche / Organisatorische Einheiten:Kaiserslautern - Fachbereich Maschinenbau und Verfahrenstechnik
DDC-Sachgruppen:6 Technik, Medizin, angewandte Wissenschaften / 620 Ingenieurwissenschaften und Maschinenbau
Sammlungen:Open-Access-Publikationsfonds
Lizenz (Deutsch):Zweitveröffentlichung