530 Physik
Refine
Year of publication
Document Type
- Preprint (159)
- Article (76)
- Doctoral Thesis (28)
- Periodical Part (21)
- Master's Thesis (11)
- Course Material (6)
- Working Paper (5)
- Diploma Thesis (3)
- Book (1)
- Periodical (1)
Is part of the Bibliography
- no (311)
Keywords
- resonances (12)
- Wannier-Stark systems (10)
- Quantum mechanics (8)
- lifetimes (8)
- Praktikum (6)
- quantum mechanics (6)
- lifetime statistics (5)
- Lasererzeugtes Plasma (3)
- entropy (3)
- localization (3)
Faculty / Organisational entity
Fast jeder zweite Mensch in Deutschland erkrankt im Laufe seines Lebens an Krebs
– so lautet eine Aussage des Robert Koch Instituts. Die Heilungschancen werden
bei einer Krebserkrankung wird stark durch den Zeitpunkt der Diagnose und Behandlung
beeinflusst. Generell gilt, je früher desto besser. Somit ist es essenziell,
dass Krebspatienten so früh wie möglich ihre Behandlung antreten. Ebenso
muss eine Unterbrechung der Therapie aus nicht-medizinischen Gründen verhindert
werden, um eine beschleunigte Repopulation der Tumorzellen zu unterbinden.
Eine der wichtigsten Formen der Krebsbehandlung ist die Strahlentherapie, die in
etwa 50 % der Fälle sowohl zur kurativen als auch zur palliativen Behandlung angewendet
wird. Innerhalb der Strahlentherapie ist der effiziente Ablauf der Prozesse
von großer Bedeutung für die Sicherheit und Effektivität der medizinischen
Behandlung bei gleichzeitiger Wirtschaftlichkeit. Für ein bestmögliches Ergebnis
müssen die Kernprozesse der Patientenaufnahme, Bildgebung, Bestrahlungsdurchführung
sowie die Abschlussuntersuchung und Nachsorge aufeinander abgestimmt
sein. Mögliche Änderungen in den synchronisierten Abläufen müssen
wohlüberlegt und gut geplant werden.
Die COVID-19 Pandemie hat Strahlentherapieeinrichtungen weltweit zu Änderungen
im Betriebsablauf gezwungen, um Schutzmaßnahmen für Patienten und Personal
zu ergreifen. Aufgrund des plötzlichen Auftretens war eine sorgfältige
Planung der Veränderungen oft nicht möglich. In Hinblick auf potentielle zukünftige
Entwicklungen ist es notwendig, die ergriffenen Maßnahmen zu bewerten und
auf Optimierungsmöglichkeiten hin zu untersuchen, um Strahlentherapie auch in
Pandemiezeiten sicherstellen zu können. Neue Ideen und Vorgaben sollten vor der
Implementierung eingehend untersucht werden. Hierzu können realitätsnahe Simulationsmodelle
dienen.
Simulationsmodelle sind potente Werkzeuge, mit denen komplexe Abläufe dargestellt,
analysiert und mögliche Anpassungen bewertet werden können. Dies macht
ein aufwendiges und möglicherweise riskantes Ausprobieren in der Praxis obsolet
und die möglichen Folgen einer Prozessänderung können bereits im Vorhinein
abgeschätzt werden.
Im Rahmen dieser Arbeit wurde ein ereignisdiskretes Simulationsmodell einer
Strahlentherapieeinrichtung zur Untersuchung und Bewertung von Prozessen einer
privaten Strahlentherapiepraxis mit und ohne Corona-Maßnahmen entwickelt.
Hierzu galt es zuerst die Frage zu beantworten, welche Aspekte der Strahlentherapieprozesse
bereits wissenschaftlich mit Methoden der ereignisdiskreten Simulation
untersucht wurden. In einer umfassenden strukturierten Literaturrecherche
wurden nach festgelegten Kriterien transparent aktuelle wissenschaftliche Veröffentlichungen
identifiziert, kategorisiert und inhaltlich analysiert. Anhand der Ergebnisse
wurde die Forschungsfrage dieser Arbeit konkretisiert und Designanforderungen
für das Simulationsmodell entwickelt.
Ziel dieser Arbeit ist die Untersuchung der Auswirkungen ausgewählter Aspekte
der COVID-19 Pandemie auf den Betriebsablauf einer privaten Strahlentherapiepraxis.
Insbesondere sollen pandemiebedingte Personalausfälle sowie der Einfluss
von Patientenscreening auf Corona-Symptome am Praxiseingang und Schutzmaßnahmen
bei der Behandlung von an COVID-19 erkrankten Patienten auf die
Praxisabläufe quantifiziert werden.
Understanding the mechanisms and controlling
the possibilities of surface nanostructuring is of crucial interest
for both fundamental science and application perspectives.
Here, we report a direct experimental observation
of laser-induced periodic surface structures (LIPSS) formed
near a predesigned gold step edge following single-pulse
femtosecond laser irradiation. Simulation results based on a
hybrid atomistic-continuum model fully support the experimental
observations. We experimentally detect nanosized
surface features with a periodicity of ∼300 nm and heights of
a few tens of nanometers.We identify two key components of
single-pulse LIPSS formation: excitation of surface plasmon
polaritons and material reorganization. Our results lay a
solid foundation toward simple and efficient usage of light
for innovative material processing technologies.
There are a lot of photonic micro- and nano-structures in nature that consist of materials with a low refractive index and that can keep up with artificial structures concerning optical properties like scattering or coloration. This work aims to understand the photonic structures in the silver ant Cataglyphis bombycina, the blue butterfly of genus Morpho, the beetle Entimus imperialis, which shows polarization-dependent reflection, and the white beetle Cyphochilus insulanus. Furthermore, corresponding micro- and nano-structures are fabricated.
Bioinspired models with the same optical properties as the investigated structures are developed and analyzed using geometric optics and finite-difference time-domain calculations. These models are qualitatively and quantitatively compared regarding their optical properties with the original structures and fabricated by direct laser writing. To mimic potential effects of material-based disorder of the natural photonic structures, a cellulose-based resist for direct laser writing is developed and examined.
Conventional resists in direct laser writing can be replaced by a resist containing cellulose derivatives. Here, different combinations of cellulose derivatives, initiators, and solvents are examined. The best performance is observed for a combination of methacrylated cellulose acetate (MACA500), 2-Isopropyl-9H-thioxanthen-9-one (ITX), and dimethyl sulfoxide (DMSO). These resists allow for direction is attained. The achieved cross-linking enables stable three-dimensional structures and, together with the possible resolution, allows to fabricate the model inspired by the white beetle Cyphochilus insulanus in the cellulose-based resist.
The silver appearance of the Cataglyphis bombycina can be completely explained with geometric optics in the prism-shaped hairs that cover its body. The more complex structures of the other three insects use photonic crystal-like material arrangements with a varying amount of disorder. The polarization dependence of the Entimus imperialis arises from a diamond structure inside the scales of the beetle and can be mimicked with a photonic woodpile crystal. The blue butterfly of the genus Morpho and the white beetle Cyphochilus insulanus both can be reduced to disordered Bragg stacks, in which the exact properties are achieved by introducing different amounts of disorder. For Cataglyphis bombycina, Entimus imperialis, and Cyphochilus insulanus, the developed bioinspired models are fabricated using conventional resists in direct laser writing. All models show a qualitative correspondence to the optical properties of the original structures.
The cellulose-based resists enable the use of polysaccharides in direct laser writing and the concepts can be transferred to other polysaccharides, like chitin. The analysis of the different natural photonic structures and the developed bioinspired models reveal a material independence of the structures that allows the fabrication of these models in different transparent materials.
Multi-color laser excitation of diamond nitrogen vacancy centers embedded in nanophotonic structures
(2021)
Negatively charged nitrogen vacancy centers (NV−) in diamond serve as highly sensitive, optically readable sensors for magnetic fields.
Improved sensing approaches rely on NV− centers embedded in diamond nanopillar waveguides, which enable scanning probe imaging
and use multi-color laser schemes for efficient spin readout. In this work, we investigate the free-beam coupling of the most relevant laser
wavelengths to diamond nanopillars with different geometries. We focus on cylindrical pillars, conical pillars, and conical pillars with an
added parabolic dome. We study the effects of the pillar geometry, NV− position, laser wavelength, position of laser focus, and excitation
geometry (excitation from the top facet or from the substrate side). We find a pronounced impact of the laser wavelength that should be
considered in multi-color excitation of NV−. Within the pillars, exciting laser fields can be enhanced up to a factor of 11.12 compared to bulk.
When focusing the laser to the interface between the substrate and the nanopillar, even up to 29.78-fold enhancement is possible. Our results
are in accordance with the experimental findings for green laser excitation of NV− in different pillar geometries
Individual nitrogen vacancy (NV) color centers in diamond are versatile, spin-based quantum sensors. Coherently controlling the spin of NV centers using microwaves in a typical frequency range between 2.5 and 3.5 GHz is necessary for sensing applications. In this work, we present a stripline-based, planar, Ω-shaped microwave antenna that enables one to reliably manipulate NV spins. We found an optimal antenna design using finite integral simulations. We fabricated our antennas on low-cost, transparent glass substrate. We created highly uniform microwave fields in areas of roughly 400 × 400 μm2 while realizing high Rabi frequencies of up to 10 MHz in an ensemble of NV centers.
Messtechnische Bestimmung der Outputfaktoren für die roboter-gestützte Hochpräzisionsbestrahlung
(2021)
Als ein Teilbereich der Strahlentherapie fokussiert sich die Radiochirurgie auf klar abgrenzbare und nicht allzu große Tumore. Durch eine Eskalation der eingestrahlten Dosis in wenigen Fraktionen wird eine bessere Tumorkontrolle angestrebt. Allerdings wird hierbei das therapeutische Fenster weiter verkleinert. Um dieses schmale Fenster optimal zu nutzen, muss der Dosisgradient hin zum Normalgewebe extrem steil sein. Des Weiteren müssen sehr kleine Feldgrößen wählbar sein um eine sehr gute Dosiskonformität zu erzielen. Die Unschärfen der Einzelschritte der Therapiekette sollten minimal sein. Um diese Anforderungen an die geometrische, dosimetrische und letztlich an die Genauigkeit des Gesamtsystems zu erfüllen, sind dedizierte Geräte notwendig. Als dediziertes Gerät für die Radiochirurgie nutzt das Cyberknife© VSI (Fa. Accuray, Sunnyvale, CA, USA) die Kombination vieler kleiner Felder von 60 mm bis zu 5 mm Durchmesser unter verschiedenen Einstrahlrichtungen um die Dosis selbst bei irregulär geformten Tumoren hochkonformal, unter maximaler Schonung des umgebenden Gewebes, anzupassen. Durch die nichtisozentrische Feldanordnung wird dies noch einmal verbessert. Voraussetzung neben der geometrischen Präzision ist die exakte dosimetrische Berechnung der einzelnen, kleinen Felder aus denen letztlich die Gesamtdosis resultiert. Doch gerade die Kleinfelddosimetrie ist hochempfindlich und daher oftmals mit Fehlern behaftet. Neben der Positioniergenauigkeit, ist die Auswahl der geeigneten Detektoren in Bezug auf Größe und Material, für die Messung der kleinen Felder, besonders wichtig. Insbesondere die korrekte Bestimmung der Wasser-Energiedosis auf dem Zentrahlstrahl, aufgrund des fehlenden lateralen Sekundärelektronengleichgewichts, bleibt auch bei der Verwendung geeigneter Detektoren fehleranfällig. Als Outputfakor bzw. auch totaler Streufaktor, wird das Verhältnis der Dosis auf dem Zentrahlstrahl eines beliebigen Feldes zu einem Referenzfeld bezeichnet. Um eine Gesamtungenauigkeit in der Dosisberechnung von 5 % einzuhalten, ist es notwendig eben diese Outputfaktoren mit einer Unsicherheit von < 3 % zu bestimmen. Ziel der Arbeit ist es anhand verschiedener, für diesen Messzweck geeigneten, Detektoren die Outputfaktoren für die fixen Rundkollimatoren sowie für die Iriskollimatoren des Cyberknife© VSI Systems (Fa. Accuray, Sunnyvale, CA, USA) zu bestimmen. Das Augenmerk gilt hierbei den Feldgrößen kleiner als 25 mm. Ab dieser Feldgröße herrscht aufgrund der Photonengrenzenergie von 6 MeV kein laterales Sekundärelektronengleichgewicht, da die Reichweite der Elektronen größer als die betrachtete Feldgröße ist. Somit lassen sich die Outputfaktoren bzw. totale Streufaktoren nicht direkt mit den zur Verfügung stehenden Messmitteln messen, sondern müssen mit detektorspezifischen Korrekturfaktoren bestimmt werden. Die gemessenen Outputfaktoren werden ausgewertet und mit den Ergebnissen in der Literatur diskutiert. Aus den Ergebnissen der verschiedenen Detektoren soll ein gemittelter Wert abgeleitet und für die Dosisberechnungsalgorithmen als Basisdaten übernommen werden und zu einer Erhöhung der Gesamtgenauigkeit führen.
Scattering and scattering plates have a large diversity of applications. Scattering of optical and THz electromagnetic waves can be performed
with Galois scattering plates, which had found applications in acoustics first (i.e., with sound waves in concert hall acoustics). For binary
Galois scattering plates, the single scattering entities, i.e., mesas (for a binary 1) or voids (for a binary 0), have characteristic lateral dimensions
of half the wavelength of the electromagnetic waves to be scattered. Their optimal height is a quarter of the wavelength for plates used in
reflection. Meanwhile, not too elaborate lithographic techniques allow for the implementation of Galois plates for the THz range and even
for the visible spectral range. We had reported on such scattering plates before. However, in this paper, also the mathematical concept is
described and the fabrication technologies are emphasized. In contrast to the case of scattering plates with irregular surface morphologies,
Galois plate scattering is not diffuse, but there are many scattering/diffraction orders.
Spatial optical Fourier filtering is a widespread technique for in situ image or light
field processing. However, conventional fixed absorbing patterns or mechanical irises only allow
an inflexible, very restricted control. Thus, we present two electrochromic spatial filters with
ring-shaped or directional segments, which can be individually addressed and continuously tuned
in transmission resulting in up to 512 different filtering states. For realization of the electrochromic
devices, we overcome technical obstacles to realize seamless, gap-free electrochromic segments.
We describe this novel fabrication process and demonstrate the successful application in an
optical Fourier transform set-up.
We present a study of optoelectronically active Ga(As)As quantum dots (QDs) on Al-rich AlxGa1-xAs layers with Al concentrations
up to x=90%. So far, however, it has not been possible to grow optoelectronically active Ga(As)As QDs epitaxially
directly on and in between Al-rich barrier layers in the AlGaInAsSb material system. A QD morphology might appear on the
growth front, but the QD-like entities will not luminesce. Here, we use photoluminescence (PL) measurements to show that thin
Al-free capsule layers between Al-rich barrier layers and the QD layers can solve this problem; this way, the QDs become
optoelectronically active; that is, the dots become QDs. We consider antimonide QDs, that is, Ga(As)Sb QDs, either on GaAs for
comparison or on AlxGa1-xAs barriers (x >10%) with GaAs capsule layers in between. We also discuss the influence of QD
coupling both due to stress/strain from neighboring QDs and quantum-mechanically on the wavelength of the photoluminescence
peak. Due to their mere existence, the capsule layers alter the barriers by becoming part of them. Quantum dots
applications such as QD semiconductor lasers for spectroscopy or QDs as binary storage cells will profit from this additional
degree of design freedom.
Reflectance anisotropy spectroscopy (RAS), which was originally invented to monitor
epitaxial growth, can—as we have previously shown—also be used to monitor the reactive ion
etching of III/V semiconductor samples in situ and in real time, as long as the etching rate is not
too high and the abrasion at the etch front is not totally chaotic. Moreover, we have proven that—
using RAS equipment and optical Fabry-Perot oscillations due to the ever-shrinking thickness of the
uppermost etched layer—the in situ etch-depth resolution can be as good as +/-0.8 nm, employing a
Vernier-scale type measurement and evaluation procedure. Nominally, this amounts to +/-1.3 lattice
constants in our exemplary material system, AlGaAsSb, on a GaAs or GaSb substrate. In this
contribution, we show that resolutions of about +/-5.6 nm can be reliably achieved without a Vernier
scale protocol by employing thin doped layers or sharp interfaces between differently doped layers
or quantum-dot (QD) layers as etch-stop indicators. These indicator layers can either be added
to the device layer design on purpose or be part of it incidentally due to the functionality of the
device. For typical etch rates in the range of 0.7 to 1.3 nm/s (that is, about 40 to 80 nm/min), the RAS
spectrum will show a distinct change even for very thin indicator layers, which allows for the precise
termination of the etch run.