Refine
Document Type
- Article (3)
- Doctoral Thesis (1)
Has Fulltext
- yes (4)
Keywords
- Differentialgleichung des Sandwichtheorie (1)
- Faserverstärkter Kunststoff (1)
- Mehrschichtige Stahlbetonwandtafel (1)
- basalt fibre reinforced polymer (1)
- concrete composite structures (1)
- concrete sandwich panels (1)
- fibre-reinforced polymer connectors (1)
- fire resistance (1)
- fire test (1)
- fire wall (1)
Faculty / Organisational entity
Die Kopplung der Schalen mehrschichtiger Stahlbetonwandtafeln mit innenliegender
Wärmedämmung kann mit stabförmigen Verbindungsmitteln aus
glasfaserverstärktem Kunststoff (GFK) erfolgen. Diese Verankerungen weisen
gegenüber Edelstahlverankerungen Vorteile hinsichtlich der Dauerhaftigkeit und des
thermischen Verhaltens auf. Infolge der begrenzten Verformbarkeit der
Verbindungsmittel und zur Sicherstellung der Verankerung der Verbindungsmittel in
den Schalen sind für die Wandelemente neben den Nachweisen zur Tragfähigkeit
auch Nachweise im Grenzzustand der Gebrauchstauglichkeit zu führen.
Gegenstand der vorliegenden Arbeit ist die wirklichkeitsnahe Ermittlung der
Schnittgrößen in der Vorsatzschale und die Berechnung der Relativverschiebung
zwischen den Schalen als Grundlage der Nachweiseführung. Insbesondere bei
hohen, schlanken Wandelementen ist das Verbundtragverhalten unter Einbeziehung
der innenliegenden Wärmedämmschicht dieser Bauteile zu berücksichtigen.
In einem ersten Bearbeitungsschritt erfolgt ein umfangreiches Versuchsprogramm
zur Analyse des Last-Verformungsverhaltens der Verbundfuge unter
Scherbeanspruchung. Darauf basierend wird ein mechanisches Modell entwickelt,
das eine allgemeingültige Berechnung der Verbundfugensteifigkeit als Grundlage der
weiteren Untersuchungen ermöglicht.
Aufbauend auf diesen Erkenntnissen werden in einem zweiten Bearbeitungsschritt
Lösungen dargelegt, welche die Berechnung der Funktionsverläufe der Schnitt- und
Verformungsgrößen aus der Verbundtragwirkung ermöglichen. Grundlage ist das
gekoppelte Differentialgleichungssystem der Sandwichtheorie. Für relevante Lastfälle
und Lagerungsbedingungen werden geschlossene, analytische Gleichungen zur
Berechnung der Extremalwerte erarbeitet. Das Berechnungsmodell wird im Rahmen
einer Versuchsreihe an mehrschichtigen Stahlbetonplattenstreifen mit den
Versuchsergebnissen verifiziert. Zur Abgrenzung von Fällen, bei denen auf eine
aufwändige Berücksichtigung der Verbundtragwirkung verzichtet werden kann,
werden Parameterstudien durchgeführt und praxisrelevante Fälle ausgewertet.
Abschließend werden grafische Berechnungshilfsmittel zur Ermittlung der maximalen
Zustandsgrößen infolge der Verbundtragwirkung angegeben.
Im dritten Teil der Arbeit wird der spezielle Fall des Einflusses einer
Ortbetonverfüllung auf das Schnittkraft- und Verformungsverhalten mehrschichtiger
Stahlbetonwandelemente betrachtet. Im Ergebnis der Untersuchungen wird
festgestellt, dass der Betonierdruck eine dauerhafte, nicht zu vernachlässigende
Vorspannung der Verbindungsmittel zur Folge hat. Für die Bemessung der
Verbindungsmittel unter Zugbeanspruchung wird empfohlen, 40% des rechnerischen
Frischbetondrucks als Zugbeanspruchung auf die Verbindungsmittel anzusetzen.
Weiterführende Untersuchungen zum Einfluss der Fugenvorspannung auf die
Schnitt- und Verformungsgrößen infolge Verbundwirkung ergeben, dass diese nicht
signifikant ist.
Precast concrete sandwich panels (PCSPs) are known for their good thermal, acoustic
and structural properties. Severe environmental demands can be met by PCSPs due to their use of
highly thermally insulating materials and non-metallic connectors. One of the main issues limiting
the wider use of sandwich walls in construction is their unknown fire resistance. Furthermore,
the actual behaviour of connectors and insulation in fire in terms of their mechanical performance
and their impact on fire spread and the fire resistance of walls is not fully understood. This paper
presents an experimental investigation on the structural and thermal behaviour of PCSPs with
mineral-wool insulation and glass-fiber-reinforced polymeric bar connectors coupling two concrete
wythes. Three full-size walls were tested following the REI certification test procedure for fire walls
under fire and vertical eccentric and post-fire mechanical impact load. The three test configurations
were adopted for the assessment of the connectors’ fire behaviour and its impact on the general
fire resistance of the walls. All the specimens met the REI 120-M criteria. The connectors did not
contribute to the fire’s spread and the integrity of the walls was maintained throughout the testing
time. This was also confirmed in the most unfavourable test configuration, in which some of the
connectors in the inner area of the wall were significantly damaged, and yet the structural connection
of the concrete wythes was maintained. The walls experienced heavy heat-induced thermal bowing.
The significant contribution of connectors to the stiffness of the wall during fire was observed and discussed.
High performance fiber-reinforced concrete (HPFRC) has been frequently investigated in recent years. Plenty of studies have focused on different materials and types of fibers in combination with the concrete matrix. Experimental tests show that fiber dosage improves the energy absorption capacity of concrete and enhances the robustness of concrete elements. Fiber reinforced concrete has also been illustrated to be a material for developing infrastructure sustainability in RC elements like façade plates, columns, beams, or walls. Due to increasing costs of the produced fiber reinforced
concrete and to ensure the serviceability limit state of construction elements, there is a demand to analyze the necessary fiber dosage in the concrete composition. It is expected that the surface and length of used fiber in combination with their dosage influence the structure of fresh and hardened concrete. This work presents an investigation of the mechanical parameters of HPFRC with different polymer fiber dosage. Tests were carried out on a mixture with polypropylene and
polyvinyl alcohol fiber with dosages of 15, 25, and 35 kg/m3 as well as with control concrete without fiber. Differences were observed in the compressive strength and in the modulus of elasticity as well
as in the flexural and splitting tensile strength. The flexural tensile strength test was conducted on two different element shapes: square panel and beam samples. These mechanical properties could
lead to recommendations for designers of façade elements made of HPFRC.
The level of energy consumption in renovation activities of buildings has huge advantages
over the demolition of old buildings and the construction of new structures. Such renovation activities
are usually associated with the simultaneous strengthening of their elements, such as externally
bonded carbon fibre reinforced polymer (CFRP) lamellas or sheets on vertical and horizontal surfaces
as structural reinforcements. This means the process of refurbishing a building, as well as the
raw materials themselves have a significant impact on CO2 emissions and energy consumption.
This research paper demonstrates possibilities of replacing state of the art, highly energy-intensive
CFRP lamellas with basalt fibre reinforced plastics as energy-efficient structural reinforcements for
building constructions. The mechanical and thermal properties of basalt fibre reinforced polymer
(BFRP) composites with variable matrix formulations are investigated. The article considers macroand
microstructures of innovative BFRP. The investigations focus on fibre–matrix interactions with
different sizing formulations and their effect on the tensile strength, strain as well as modulus
of elasticity.