Influence of the Measurement Resolution on the Filtration Analysis: An Improved Test Setup According to VDI 2762 Guideline

  • Specific parameters of cake filtration, such as the filter cake and filter medium resistances, can be determined using the pressurized housing cell standardized in the guideline VDI 2762 by measuring the filtrate mass on a laboratory scale. For reproducible measurements and an exact detection of the filtration start, an improved test setup is presented and compared with a standard setup according to the guideline VDI 2762. On the basis of measurements without and with a particle system to be filtered, it is shown that the characteristic nonlinear course at the beginning of each filtration, which can be seen in the t/V-V diagram, is influenced by the used measuring equipment.
Metadaten
Verfasser*innenangaben:Nikolai BenzORCiD, Philipp LöschORCiD, Sergiy AntonyukORCiD
URN:urn:nbn:de:hbz:386-kluedo-73450
Titel des übergeordneten Werkes (Englisch):Processes
Verlag:MDPI
Dokumentart:Wissenschaftlicher Artikel
Sprache der Veröffentlichung:Englisch
Datum der Veröffentlichung (online):17.01.2023
Jahr der Erstveröffentlichung:2023
Veröffentlichende Institution:Rheinland-Pfälzische Technische Universität Kaiserslautern-Landau
Datum der Publikation (Server):20.07.2023
Ausgabe / Heft:2023, 11(2), 299
Seitenzahl:13
Quelle:10.3390/ pr11020299
Fachbereiche / Organisatorische Einheiten:Kaiserslautern - Fachbereich Maschinenbau und Verfahrenstechnik
DDC-Sachgruppen:6 Technik, Medizin, angewandte Wissenschaften / 620 Ingenieurwissenschaften und Maschinenbau
Sammlungen:Open-Access-Publikationsfonds
Lizenz (Deutsch):Zweitveröffentlichung